南非土木工程施工标准 S部分 残疾人专用设施 英文原文节选 20100079 3-19 |
SS3.2 Where such lift is operated automatically, it shall comply with the following requirements: (a) Audible and visual warnings shall be provided in the lift lobby to indicate the opening of the lift doors. (b) Any control required to be operated by a passenger in such lift shall be positioned not higher than 1,2 m above the floor level of such lift. (c) The light level on the control panel in such lift shall be not less than 50 lux. ss4 DOORS In any building contemplated in regulation S1 - (a) the leaf of any single door and at least one leaf of a double door when in the 90° position shall provide a clear opening not less than 750 mm wide at right angles to the direction of travel. (b) any handle fitted to a doorleaf of any door in an emergency route or in a feeder route or in any compartment containing toilet facilities for use by disabled persons shall be of the lever type and be installed at a height of not more than 1,2 m above floor level. (c) any difference in level of the surface of a floor at any threshold shall be not more than 15 mm . ss5 TOILET FACl LlTlES SS5.1 In any building contemplated in regulation S1 there shall be one or more WC pans suitable for use by persons in a wheelchair: Provided that - bedrooms are provided with private toilet facilities, at least one such bedroom in every 100 or part thereof shall be provided with a WC pan, washbasin and bath or shower for disabled persons; bedrooms do not have private toilet facilities, there shall be provided, on each floor, at least one compartment containing a WC pan and a washbasin, and one containing a bath or shower or disabled persons; (a) in any building which is a hotel, lodging house or hostel where - (i) (ii) SABS 0400-1990 154 SS5.2 ss5.3 (b) in any building, not being a building comtemplated in paragraph (a), where in terms of rule PP13 a combined total of more than 20 WC pans and urinals are required to serve the total population, not less than two WC pans shall be provided for the use of disabled persons; and (c) any disabled person shall not be required to travel, from any point in such building accessible to such person, a distance of more than 200 m in order to reach any compartment containing such WC pan. (a) In any building where separate sanitary fixtures are required for each sex, any two compartments required to contain a WC pan or bath or shower, irrespective of the sex for which they are provided, may be replaced by one such compartment provided for the use of disabled persons of both sexes: Provided that the total number of sanitary fixtures is adequate. (b) The door of any such compartment containing toilet facilities shall be either a sliding door or, if hinged, shall open outwards, and where a locking device is fitted, the doorleaf shall be openable from the outside by the use of a suitable device, and such leaf shall be fitted with a suitable means of indicating whether the compartment is occupied. (c) Any compartment containing a WC pan for the use of disabled persons shall have a minimum area of 2,9 m2 and a minimum plan dimension of 1,6 m . (d) A distance of not less than 450 mm or not more than 500 mm shall be provided between the centre line of the WC pan and the nearer side wall of such compartment, and approved grab bars shall be fixed to such nearer wall and the rear wail. (e) The distance from the front edge of the WC pan to ?he rear wall of such compartment shall be not less than 660 mm . (f) The top surface of the seat of the WC pan shall be not less than 460 mm and not more than 480 mm above the floor level. (9) Unless the WC pan is provided with a special back rest, the lid and seat thereof, when raised to the upright position, shall remain in such position. (h) The pan flushing control and toilet-paper holder shall be easily accessible to any person in a wheelchair. (a) Within any such compartment the washbasin shall be mounted without legs or pedestal, and the height from the floor to the top edge of such basin shall be not more than 830 mm . (b) Such washbasin shall have a vertical clearance of 650 mm from under the basin to the floor, measured at a point not less than 160 mm from the front of and under the basin. (c) Where a vanity slab is fitted in such compartment, the distance from the edge of the facia to the inside of the bowl of the washbasin in such slab shall be not more than 80 mm, and such slab shall have a vertical clearance of 680 mm measured from the floor to the underside of the facia. (d) Water taps supplying such washbasin shall be operated by lever handles, and the cold-water tap shall be within reach of any person sitting on the WC pan. ss5.4 Any bath or shower cubicle provided for the use of disabled persons shall be so designed and positioned as to allow a person in a wheelchair to transfer to a seat in such bath or cubicle. SS6 AUDITORIA AND HALLS Where any building contemplated in regulation S1 contains one or more auditoria or halls fitted with fixed seating, floor space accessible to any person in a wheeichair shall be set aside for the accommodation of wheelchairs in such auditoria or halls and - (a) such space shall be situated adjacent to an exit door and shall be so arranged that any wheelchair will not obstruct any aisle or exit door; and (b) such space shall be of a size sufficient to accommodate - 155 SABS 0400-1990 (i) one wheelchair where the number of fixed seats for which the auditorium or hall is designed is not more than 50; (ii) two wheelchairs where the number of fixed seats for which the auditorium or hall is designed is more than 50 but not more than 400; and (iii) three wheelchairs or a number of wheelchairs equal to 0,5% of the number of fixed seats for which the auditorium or hall is designed, whichever is the greater, where such number of fixed seats is more than 400. ss7 OBSTRUCTIONS IN PATH OF TRAVEL Where in any building contemplated in regulation S1 - (a) the difference in levels at any step or other change in level in the floor along any path of travel is more than 25 mm a suitable ramp from one level to the other shall be provided for the use of disabled persons; (b) any part of a building, sign, light-fitting or other object protrudes more than 300 mm into or hangs over any path of travel and has a clearance of less than 2 m above the traff icable surface, a barrier commencing not higher than 300 mm above such surface shall be provided to indicate the presence and position of the inadequate headroom above. SS8 PARK1 N G Where provision has been made within any building contemplated in regulation S1, or on the site on which such building is erected, for the parking of more than 50 motor vehicles - (a) At least one parking space per 200 or part thereof of the total number of parking spaces shall be provided for parking of vehicles used by disabled persons; (b) any parking space provided for vehicles used by disabled persons shall be of an approved length, shall be not less than 3,5 m wide and shall be situated on a level surface; (c) such parking space shall be located as near as possible to the means of access contemplated in subregulation S2(2) and (3) and shall be accessible thereto; (d) such parking space shall be clearly demarcated as being intended for the use of disabled persons only. ss9 ss9.1 INDICATION OF EXISTENCE OF FACILITIES Where facilities for disabled persons have been provided in or in connection with any building, the existence and position of such facilities shall be indicated by - (a) exhibiting externally at the main entrance of and at any other approved position in such building, the international symbol as depicted in Appendix 1 to this code; and (b) exhibiting internally, in approved positions, such symbol, which shall be clearly visible, to indicate to disabled persons the route to and the entrance to such facilities. SS9.2 The size of any such symbol shall be not less than 100 mm x 100 mm, and the symbol of a person in a wheelchair shall be in the colour yellow on a black background.原件下载:
|
|
|
|